This is an old revision of the document!


Devices

Draytek - Vigor 3200

General

Compatible 8
Recommended 8
VPN subnet to subnet

Mikrotik

General

Compatible 8
Recommended 7
VPN subnet to subnet

SA Src. Address: is the ip address where we expect the pkts ipsec, ex: the device ip or gateway when behind NAT
SA Dst. Address: is the ip address where we expect the pkts ipsec, ex: the CM ip

Setting VPN using the terminal

Schema:

LAN-MK MK CM LAN-CM
172.26.7.0/24 192.168.20.1 192.168.10.1 10.10.2.0/24

Commands:

/ip ipsec peer add address=192.168.10.1/32 port=500 auth-method=pre-shared-key secret=“PSKEYSECRET2013”

/ip ipsec policy add src-address=172.26.7.0/24 src-port=any dst-address=10.10.2.0/24 dst-port=any sa-src-address=192.168.20.1 sa-dst-address=192.168.10.1 tunnel=yes action=encrypt proposal=default

/ip firewall nat add chain=srcnat action=accept place-before=0 src-address=172.26.7.0/24 dst-address=10.10.2.0/24

SONICWALL

General

Compatible 8
Recommended 8
VPN subnet to subnet

Zyxel

ZyWall USG 20

General

Compatible 8
Recommended 8
VPN subnet to subnet

P-661HW-D1

General

Compatible 8
Recommended 8
VPN subnet to subnet